GREEN POWER GP 210 S/G-A Generating Set 210 KVA Automatic Supersilenced

GREEN POWER GP6A/KW-C
GREEN POWER GP6A/KW-C
GREEN POWER GP6A/KW-C
GREEN POWER GP6A/KW-C
GREEN POWER GP6A/KW-C
GREEN POWER GP6A/KW-C
GP 210 S/G-A MA

Fuel: Natural Gas / LPG
Standby power at cosfì 0.8: 210 KVA
Prime power at cosfì 0.8: 198 KVA 
Standby power at cosfì 0.8: 174 KW
Prime power at cosfì 0.8: 158 KW
Voltage available to the terminals: 230/400 V
Dimensions (mm): 3800x1100x2100 mm
Weight: 2700 Kg approx.
1500 rpm
Electronic governor: ISO 3046
Alternator: MECC ALTE ECO 38-2 SN

Download Technical Data GP 210 S/G-A
 
Phase
Three phase
Maximum power three phase (KW)
4.4
Continuous power three phase (KW)
4
Maximum power three phase (KVA)
5.5
Continuous power three phase (KVA)
5
Fuel
LPG / Natural Gas
Frequency (Hz)
50
Voltage (V)
230 / 400
Sockets configuration
Terminals
Engine
KOHLER KDW702
Engine rpm (rpm)
1500
Speed governor
Mechanical
Starting system
Automatico
Engine capacity (cm³)
686
Number cylinders
3
Cooling
Water
Alternator
LINZ E1S13SA/4
Poles
4
Protection degree
IP23
Motor insulation class
H
Mechanical power (hp)
262
Battery type
Lead acid
Consumption (L/h)
4 al 75% del carico
Acoustic pressure
70 dB(A) at 7 m
Length (mm)
1300
Width (mm)
700
Height (mm)
1000
Dry weight (Kg)
350
Silenced
Yes
Super silenced
Yes
Brushes
No
ATS Switch device
Optional ATS
Type of alternator
Constant Speed
Voltage regulator
AVR
Engine manufacturer
Doosan
Brand

Model: supersilenced 70dB(A)±3 at 7mt
Engine/alternator monoblock unit coupled through flexi-disc couplings, installed on a welded steel baseframe,complete with antivibration mountings.
Soundproof enclosure with doors made of 20/10 sheet steel, soundproof material, internal silencer,steel handles and hinges, internal fuel tank cap, lifting hook, powder painting.

Electronic control unit and a programmable microprocessor, LCD display with backlight Off/Auto/test controls, Display of all parameters of the engine and alternator.
Diagnostic information of the gen set, Automatic and manual control of the contactors, Mains voltage (on 3 phases), gen set voltage (on 3 phases), 3 gen set current, mains and gen set frequency, RPM counter, Vdc Battery, D+Voltage, KW-KVA-KWh – cosfi average.25 alarm messages and 9 pre alarm.
Alarm history, Overvoltage / under voltage shutdown, overfrequency shutdown, overload shutdown, Short circuit shutdown.

Complete your order with:

16 other products in the same category:

Product added to wishlist
Product added to compare.